5.1
wiring diagram
WARNING
!
•
Do not wire 110 volts to the valve or wall switch.
TRANSFORMER
BATTERY
HOUSING
DISCONNECT THESE
CONNECTIONS TO THE
ON/OFF SWITCH. CONNECT
AN OPTIONAL THERMOSTAT
OR REMOTE CONTROL AND
(IF ALLOWED WITH THIS
APPLIANCE) A "B" VENT
DC SUPPLY
WHERE APPLICABLE, APPLIANCES WITH "B" VENT ADAPTORS MUST HAVE THE SPILL SWITCH WIRED IN
SERIES WITH EITHER THE EXISTING SWITCH OR OPTIONAL WALL SWITCH, THERMOSTAT OR REMOTE.
note:
This appliance comes equipped with a battery back-up. If this backup is used, install 4 'AA' batteries (not sup-
plied) into the holder and connect to the wire harness. Connect the battery holder to the wire harness before
using the appliance. Place near the IPI board. If the backup is used, it must be connect to this 6 volt battery
pack (supplied).
*Some jurisdisctions may prohibit the use of a standing pilot. In
ACS/IPI
these jurisdictions, the anti-condensation switch shall be
SWITCH*
disconnected to comply with local codes. To disconnect,
(OPTIONAL)
locate the white connector at the end of the white and blue
wires of the ACS switch and disconnect.
ON / OFF
SWITCH
IPI / CPI*
ON / OFF
ADAPTOR.
GROUND
DFC
Digital Fireplace Control
DC
Direct Current
IPI
Intermittent Pilot Ignition
CPI
Continuous Pilot Ignition
ACS
Anti-Condensation Switch
5.0 electrical information
ORANGE
VALVE
GROUND
EYELET
Legend
GREEN
ELECTRONIC
VALVE
IPI BOARD
DFC
-
W415-1613 / F / 03.12.19