Customer:
Address:
Date of Installation:
Location of appliance:
Installer:
Dealer/Distributor contact number:
Serial #:
Model:
Natural Gas:
B46NTR
B46NTRE
1.0 general information
When the appliance is installed at elevations above 4,500 ft (1371m), and in the absence of specifi c
recommendations from the local authority having jurisdiction, the certifi ed high altitude input rating shall be
reduced at the rate of 4% for each additional 1,000 ft (305m). Expansion / contraction noises during heating up
and cooling down cycles are normal and are to be expected.
This appliance is approved for bathroom, bedroom, and bed-sitting room installations and is suitable for mobile
home installation.
PRODUCT CODES B46NTR AND B46PTR ONLY: No external electricity (110 volts or 24 volts) is
required for the gas millivolt system operation.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certifi ed kit is used.
note:
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
appliance and must be installed.
The protective wrap on plated parts is best removed when the assembly is at room temperature but this can be
improved if the assembly is warmed, using a hair dryer or similar heat source.
This appliance is a decorative product. It is not a source of heat and not intended to burn solid fuel.
Batteries must be disposed of according to the local laws and regulations. Some batteries may be
recycled, and may be accepted for disposal at your local recycling center. Check with your
municipality for recycling instructions.
1.1
rates and effi ciencies
For your satisfaction, this appliance has been test-fi red to assure its operation and quality!
Altitude (FT)
Max. Input (BTU/hr)
Min. Inlet Gas Supply Pressure
Max. Inlet Gas Supply Pressure
Manifold Pressure (Under Flow Conditions)
* Max. inlet pressure not to exceed 13".
Installer, please fi ll out the following information:
Propane:
RATES AND EFFICIENCIES
4.5" (11mb) Water Column
7"* (17mb) Water Column
3.5" (9mb) Water Column
standard checklist
B46PTR
B46PTRE
NG
0-4,500
22,000
11" (27mb) Water Column
13" (32mb) Water Column
10" (25mb) Water Column
P
0-4,500
22,000
W415-1613 / F / 03.12.19
EN
5