HIS APPLIANCE SHOULD BE INSTALLED BY A QUALIFIED TECHNICIAN / INSTALLER
• Prior to installation, ensure that the
local distribution conditions (nature of the gas
and gas pressure) and the adjustment condi-
tions of the appliance are compatible.
•
These hobs are designed to be used by
private individuals in their homes. The adjustment
conditions are stated on a label in the bag and al-
so on the packaging.
•
Since this appliance is not connected to a
combustion products evacuation device, it must
be installed in accordance with current installation
regulations and used in a well-ventilated place.
Particular attention should be given to the relevant
requirements regarding ventilation.
B B U U I I L L D D I I N N G G I I N N T T O O A A U U N N I I T T
i i
o o
n n
i i
o o
n n
Brûleur
rapide
Brûleur
double couronne
r r
t t
h h
e e
i i
n n
s s
o o
r r
t t
h h
e e
i i
n n
s s
Brûleur
grand-rapide
t t
a a
l l
l l
e e
r r
t t
a a
l l
l l
e e
r r
•
only if oxygen from the air is present, so this air must
be constantly renewed and the combustion
products must be evacuated (a minimum air input of
2 m3/hour per kW of gas energy is required).
•
60.335.2.6 against overheating of cupboards and
Class 3 for installation itself (in accordance with
standard EN 30.1.1).
•
port cupboard. This worktop must be at least 3 cm
thick and heat-resistant or else coated with a heat re-
sistant material.
•
to the right and left of the hob. A tall cupboard or par-
tition too close to the hob would hinder free move-
ment of kitchen ustensils.
•
must be placed between 10 and 15 cm from the bot-
tom of the worktop. In any case, do not keep any
sprays or pressurized containers in the compartment
which could be just under the hob.
-15-
Brûleur
auxiliaire
Brûleur
semi-rapide
On this subject, combustion can take place
Example : hob 5 gas burners :
Total power :
0,85 + 1,5 + 2,3 + 3,3 + 4 = 11,95 kW.
11,95 kW x 2 = 23,90 m3/hour minimum air
input.
These hobs in accordance with standard EN
The hob must be built into the worktop of a sup-
A side-clearance of at least 30 cm should be left
If a horizontal partition is put under the hob, it
.