Avoid installing the camera facing a light source, as images of visitors may be impaired.
We recommend that silicon sealant is applied between the rain shield and the wall/pillar (but not below the rain shield) and that the door station is fitted
at a height of approximately 1.60 m.
[1]. Route all the cables into the rain shield.
[2]. Fix the rain shield to the wall/pillar.
[3]. Connect:
• the monitor cable to the first 2 terminals on the door station:
M+ of the monitor to M+ of the door station
M- of the monitor to M- of the door station
• the electric latch/lock cable to terminals L+ and L- of the door
station.
• the motorisation cable to the dry contact output (COM and NO) of
the door station
Note: To feed the cables into the terminals, use a screwdriver to
press on the square with the notch, feed the wires in, then release.
[4]. Position the door station in the rain shield.
[5]. Screw the door station to the rain shield using the tamper-proof