Parameterization
The parameterization of the unit is done in a menu. To start the menu press both
menu buttons simultaneously (approx. 1 sec.) until the first menu item appears on the
display. Now, you can navigate in the menu as follows:
Next menu item:
Page menu items forward:
Previous menu item:
Page menu items backward:
Next setting:
Page settings forward:
Previous setting:
Page setting backward:
Shortly press menu button [ ] in menu item U to quit the menu. Depending on the
setting in menu item U, the settings you made will be either saved (set), not saved
(escape) or the default settings will be restored with the exception of menu item 1
(default).
Canceling the menu without saving the settings made is possible by pressing both
menu buttons simultaneously (approx. 1 sec.) or will happen automatically if 60
seconds pass without a menu button being pressed.
Once the menu is closed, the unit behaves in the same manner as after power-on.
In menu mode, a control of the unit is not possible.
The menu items are listed in the following table. Default settings are marked with *.
Individual menu items or settings may be suppressed in another menu item
depending on the type of unit or setting.
Menu item
1
Interface
3
Parity
36
Shortly press menu button [ ]
Press menu button [ ] long
Double click on menu button [ ]
Double click on button [ ] and keep it pressed
Shortly press menu button [ ]
Press menu button [ ] long
Double click on menu button [ ]
Double click on button [ ] and keep it pressed
Settings
RS232 (not for Modbus control)
RS485
RS485 (4-wire bus)
RS485 (2-wire bus)
none
odd
even*
Display
1 232
1 485
1 4-4
1 4-2
3
0
3
1
3
2
BAL S102 MDB M 1.0