Wiring The Receiver Urr; Wiring The Electrical Power Supply Of Receiver Urr - Jay Electronique UR Série Notice Technique D'installation Et D'utilisation

Masquer les pouces Voir aussi pour UR Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.6.1- Wiring the receiver URR

If flexible stranded wire is used, crimped terminations should be used to avoid false contacts and short
circuits.
To open the connection terminal strips :
- Vertically insert the screwdriver (flat tip screwdriver of 1.5 to 3 mm width)
in the slot located opposite the wire,
- Insert the wire,
- Remove the screwdriver.
    
Do not apply any lever movement to the screwdriver as this can
result in damage to the terminal strip and the printed circuit on the
motherboard of the receiver URR.

5.6.2- Wiring the electrical power supply of receiver URR

Caution:
The electrical connections should be made such that when the main
switch is off, the UR remote control receiver is also deactivated.
Receiver
URR*C4*-B - ***
reference =
0V
+ 24VDC
+ 12VDC
See Annexe B for location of power supply connection terminal
For the wiring and to determine the correspondence between the action on a function button or switch
and the relay controlled, refer to the configuration table supplied with the receiver (label on housing
cover) and Appendix B.
See wiring example in appendix D for standard unit
FR
EN
- 66 -
12 - 24 VDC
1
24VAC
2
3
48VAC
DE
URR*CA*-B - ***
24/48 VAC
1
N
2
3
URR*CB*-B - ***
115/230 VAC
1
N
115VAC
2
230VAC
3
UR - 323245J

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières