2.1- Function button interlocking
The following function button interlocking configurations are possible:
électronique
*
n°3
n°4
n°1
n°2
*
(URE front panel)
For each of the desired interlocking configurations, simultaneous action on the two buttons will result
in three operating modes which depend on the programs defined:
- program n°1 :
- program n°2 :
- program n°3 :
2.2- Correspondence between function buttons and relays
In its standard configuration, the "buttons-relays" are assigned naturally by the increasing
order of the button numbers and relay numbers:
Each "BPSV" button type is assigned 1 relay.
Each "BPDV" button type pair is assigned either 3 relays (2 movement relays and a third relay for
high speed), or 4 relays. This information is contained in the URR product reference data.
Each "COM2" button type is assigned 1 relay.
Each "COM3" or "COM3R" button type is assigned 2 relays with the possibility to have both
relays either OFF or ON when the switch is in the center position. This information is contained in
the URR product data.
For non-standard "button-relay" configurations, be sure to properly fill in the configuration
sheet located in the URR cover.
FR
EN
- 50 -
1st button of
interlocked pair
Button no.1
Button no.1
Button no.1
Button no.2
Button no.2
Button no.3
*= Standard interlocking configurations defined
in sales reference for URR product (see §
3.2).
By pressing the 2 button pair, the two commands are deactivated
(corresponding relays set to OFF).
The first button of the interlocked pair has priority.
(ex.: B1-B2 interlocked: when these two buttons are pressed
simultaneously, only button B1 is acknowledged).
The 2nd button of the interlocked pair has priority.
(ex.: B2-B4 interlocked: when these two buttons are pressed
simultaneously, only button B4 is acknowledged).
DE
2nd button of
Abbreviation
interlocked pair
Button no.2
B1-B2
Button no.3
B1-B3
Button no.4
B1-B4
Button no.3
B2-B3
Button no.4
B2-B4
Button no.4
B3-B4
*
*