4.2.1- Connection to relays
Connections are made on spring terminals with connection points identified by numbers.
The flexible wire section (without end-fitting) is between 0.08 mm square and 2.5 mm square.
No common line is provided on the printed circuits (all contacts are potential-free).
An accessory (reference UDWR12) enables easy connection of the common lines desired (supplied
as a standard feature with the product).
4.2.2- Relay characteristics
Summary table of relays available on receiver
Relay function
Safety
"On" control
(Horn)
Movement or selection
control
- Characteristics of safety relays :
• Contacts : AgNi10+Au5μm
• 150 000 switching cycles at 230VAC, 6A, cosphi=1
• 100 000 switching cycles at 24VDC, 6A
• 50 000 000 switching cycles at 12VDC, 10mA (min. current)
• Tests per EN 60947-5-1 :
- Characteristics of control relays :
• Contacts : AgNi 0,15
• 120 000 switching cycles at 250VAC, 8A, cosphi=1
• 50 000 switching cycles at 24VDC, 8A
• 10 000 000 switching cycles at 12VDC, 10mA (min. current)
• Tests per EN 60947-5-1 :
- Number of switching cycles on various contactors :
Contactor
Switching at 230VAC (70VA,cosphi=0,75)
CA2DN
LC1D09
Switching at 110VAC, (70VA,cosphi=0,75)
LC1D18
LC2D09
Switching at 48VAC (70VA,cosphi=0,75)
FR
EN
- 60 -
Number of
relays
2
1
6
DC13 at 24V / 0,5A
AC15 at 230V / 2A
DC13 at 24V / 0,5A
AC15 at 230V / 2A
Physical unit switched by relay
DE
Number of connection
points per relay
2 (1 T contact)
2 (1 T contact)
2 (1 T contact)
Number of switching
cycles
Safety
relay
6
4,5x10
6
4,5x10
6
4,5x10
Control
relay
6
3x10
6
2,5x10
6
1,2x10
UR - 323245J