Menu 2 – Deleting the components
Press SELECT until the second LED from the bottom lights up.
Press SET once to go to menu 2.
The LED of a channel with a trained component starts flashing. Press SELECT again until the desired
channel flashes. Empty channels cannot be selected. If the LED of the desired channel flashes, press
(beeps once) and hold ESC/DEL (about 4 seconds) until the Terxon 2WAY wireless module beeps twice
and LED 2 lights up again. The component has been deleted. You are now automatically back in the main
menu.
If necessary press SET to get back to menu 2, and repeat the process described above.
If you want to close programming mode, press ESC/DEL until the Terxon 2WAY wireless module starts
beeping (about once per second). Close the Terxon 2WAY wireless module housing and hold the lid tamper
contact (SW4 underneath ESC/DEL) down for about 4 seconds until it beeps twice. The data is saved in an
EEPROM.
Menu 3 – Train PIN / proximity chip key
Press SELECT until the 3rd LED from the bottom lights up.
Press SET once to go to menu 3.
To train a PIN or proximity chip keys, use a wireless operating unit 2WAY, which you previously trained as
per menu 1. Please note that the wireless operating unit 2WAY must be supplied with 12 volt external
voltage so that you can use a proximity chip key.
Enter the desired 4-digit code/PIN and choose ACTIVATE ALL. Once the first code/PIN is trained, the
Terxon 2WAY wireless module beeps twice, occupies the first PIN/proximity chip key position and the LED
of the first channel flashes.
Or you move the proximity chip key in front of the wireless operating unit 2WAY until the wireless operating
unit 2WAY beeps and then press the ACTIVATE ALL key.
Once the first proximity chip key is trained, the Terxon 2WAY wireless module beeps twice, occupies the
first PIN/ proximity chip key position and the LED of the first channel flashes.
Repeat the operation for additional PINs or proximity chip keys. This assigns additional channels. Note that
a maximum of 8 channels can be assigned.
Once you're done, press ESC/DEL once to get back to the main menu.
If you want to close programming mode, press ESC/DEL until the Terxon 2WAY wireless module starts
beeping (about once per second). Close the Terxon 2WAY wireless module housing and hold the lid tamper
contact (SW4 underneath ESC/DEL) down for about 4 seconds until it beeps twice. The data is saved in an
EEPROM.
Note!
The software does not allow you to delete individual PINs or proximity chip keys. To delete PINs
or proximity chip keys, close the menu 8 factory setting. If you do this, all PIN/proximity chip
keys and all components are deleted.
44