Télécharger Imprimer la page

Customer Service And Support - Abus AZ4290 Instructions D'installation

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 54
For each input:
Max. input voltage = Vsupply (as applied on terminal block 1 terminal 1 (12 V IN))
Max. input voltage = 0 V (as applied on terminal block 1 terminal 2 (0 V IN))
V
(V_Input_Low_max) = 0.5 V (Low = 0 to 0.5 V), applied to terminal block 1 terminal 2 (0 V IN)
ILmax
V
(V_Input_Low_max) = 7 V (Low = 0 to 7 V), applied to terminal block 1 terminal 2 (0 V IN)
ILmax
Compatibility:
Tamper switch
Programming keys
Option switch:
Dimensions:
Weight:
Housing material:
HF transceiver:
Transmission range:

14. Customer service and support

End consumer:
Dealers/installers:
Terxon LX AZ4200, Terxon L AZ5200,
Terxon MX AZ4100, AZ4150, Terxon M AZ5100, AZ5150
Terxon SX AZ4000, Terxon S AZ5000
as well as alarm centres from other manufacturers
Secvest 2WAY wireless outdoor sounder FU8220
Secvest wireless indoor sounder FU8230
Wireless remote control 2WAY FU8100
Wireless control unit 2WAY FU8110
Secvest key 2WAY wireless cylinder FU59xx
Ceiling and wall
3 (SELECT, SET, ESC/DEL)
8 position DIP switch for
Supervision (On/Off)
Supervision short/long (3 h/20 min)
Jamming detection (On/Off)
Status polarity for inputs (global 0 V/12 V)
Status for outputs (global NC/NO)
PIN/proximity chip key channels or device mode
Feedback from the alarm centre, activated or internal
activated (Yes/No)
Output response (Permanent/Impulse)
136 x 223 x 42 mm (W x H x D)
330 g
ABS (thermoplastic)
Operating frequency 868.6625 MHz at 20 kHz bandwidth. I-ETS 300 220. CE-
tested as per I-ETS 300 339 (draft standard). HF transmission power: 10 mW
(antenna input), PCB antenna with diversity function.
approx. 30 m indoors (depending on environmental factors)
approx. 100 m outdoors (depending on environmental factors)
The aforementioned values are approximate. The transmission and
reception ranges of the Terxon 2WAY wireless module, the operating
elements and the signallers is highly dependent on the environment in
which they are installed. The devices' exact ranges can only be
determined by means of on-site measurements.
Please consult your dealer or installer if you have any questions.
Consult our website for product support information:
www.abus-sc.com
51