4.4 Work stage
After the 'STARTUP' stage, the stove goes to the 'WORK' mode which represents the normal operation mode.
The user can adjust the heat output from the max. value of 5 to a min. of 1 with the buttons 'P5' and 'P6'.
Dialogue box
Output set to 3
- Make sure to check the pellet level in the hopper so that the flame does not go out due to lack of
pellets.
- Make sure the stove is off when loading pellets.
- The pellet hopper lid must always remain closed; it must only be opened when loading fuel.
- The bags of pellets must be kept at least 1.5 m from the stove.
4.4.1 Modifying the room temperature setting
To modify the room temperature just select the MODIFY ROOM SET mode by pressing the button P2.
Then use the buttons 'P1' and 'P2' : the display shows the current SET temperature status.
Button 'P1'
Button 'P2'
When the fume temperature rises the maximum value set, the
display will show the message 'MODULA F' ('MODULATION F')
and the stove starts the modulation of the flame authomatically.
On the contrary when the temperature goes over 280°C the
display will show the alarm 'ALARM HOT FUMI' ('ALARM HOT
FUMES') and the stove will start the switch-off procedure.
Clock
Room temperature
Room temperature set value
Dialogue box
51
Button 'P6'
Button 'P5'
Water temperature
Real output in work
equal to 1 - flashing
Clock
Room temperature
Set output
Dialogue box
TERMO-PERLA LUX