Parameter Descriptions

Parameter
Name
Operating
d1
temperature
Temperature
d2
Differential
d3
Temperature Range
d4
Compressor Activation
d5
Time Intervals
Maximum
d6
Temperature
Differential Alarm
Temperature
d7
Differential Alarm
Delay
Defrost Cycle Time
d8
Intervals
Maximum Defrost
d9
Duration
Defrost Cut-off
d10
Temperature
Additional Cut-off
d11
Defrost Period
Delayed Actual
d12
Temperature Display
Compressor On/Off
d13
During Defrost
Evaporator Drying
d14
Time
=19
Temperature Offset
=22
Unit of Measurement
Compressor Operation
=23
During Probe Failure
Compressor 'On'
=24
Duration
Compressor 'Off'
=25
Duration
Initial Defrost After
=34
Startup
Minimum
=38
Temperature Alarm

Manual Defrost

The appliance will automatically run a defrost cycle every six hours.
Note: The cycle starts from the time the appliance is initially powered up.
To manually defrost the appliance:
Press and hold the DEFROST
1.
The defrost cycle will start immediately and the Defrost LED illuminates. The defrost will last a maximum of 30 minutes.
2.
Note: Starting a manual defrost also resets the automatic defrost timer.
The next automatic defrost will start six hours after the manual defrost has finished.
Waste water is collected in the waste water tray.
3.
3
Description
Set the operating temperature of the appliance
The Temperature Differential is the allowed temperature difference above and
below the operating temperature before the compressor starts/cuts off
Set the minimum (d3) and maximum (d4) temperatures that the appliance can
fluctuate between
Enter the minimum time interval between the compressor turning off after
turning on.
Set an alarm to sound if the temperature inside the appliance exceeds the set
operating temperature by a specified amount
Set a delay before the temperature differential alarm is triggered
Set the time between each defrost cycle
Set the maximum length of the defrost cycle
Note: The defrost duration can be overridden by parameter d10
(below), if the cut-off temperature is reached before the end of the
defrost duration
Set the defrost cut-off temperature
Set an additional amount of defrost time after the defrost cut-off point has been
reached (if required)
Set the length of time the inner temperature of the appliance (before defrost
started) is displayed for after a defrost cycle has finished
Turn the Compressor On or Off during the defrost cycle
Set the amount of time the compressor remains turned Off after a defrost cycle,
reducing the amount of frost build up
Should there be any variance between measured and actual temperature, the
measured temperature can be offset to compensate
Set whether the temperature is displayed in Centigrade or Fahrenheit
Set whether the compressor runs or remains Off during a temperature probe
failure
Set the length of time the compressor runs during a temperature probe failure
Set the length of time the compressor remains Off during a temperature probe
failure
Set whether the appliance starts a defrost cycle 10 minutes after startup or after
the time programmed in parameter d8 (Defrost Cycle Time Intervals)
Set the display to flash should the inner temperature of the appliance drop
beyond a specified point from the programmed operating temperature
button for 5 seconds.
Default Parameter
Range
-2°C to 10°C
0 to 20°C
-40°C
95°C
0-999 seconds
0°C-50°C
0-99 minutes
1-999 hours
0-999 minutes
-45°C to 50°C
0-99 minutes
0-99 minutes
On (1) or Off (0)
0-99 minutes
-20°C to 20°C
Centigrade (0) or
Fahrenheit (1)
Compressor runs (1)
Remains Off until fault fixed
(0)
Runs intermittently with
parameters =24 and =25
(2)
1-99 minutes
1-99 minutes
Begins 10 minutes after
startup (0) or when
programmed (1)
1°C to 50°C
Value
2°C
2°C
0°C
10°C
99
50
0
24
1
n/a
n/a
0
n/a
0
-5°C
0
2
10
10
n/a
40°C