AUTOMATIC MODE – If you select this operating mode, when a pulse is given,
opening is commanded until the work time expires, the gate remains open for the
selected pause time and it then closes automatically.
• If a pulse is sent during opening, the control system ignores it and the gate
continues to open.
• If a pulse is sent or the photocells are obscured during closing, the direction is
inverted (the gate re-opens).
• During the pause stage and when the photocells are obscured, the device will
remain in pause until the photocells are cleared.
SEMIAUTOMATIC MODE WITH STOP. If you select this operating mode when the
gate is closed, when a start pulse is given, the gates open until the set work time
expires. If another start pulse is given during opening, the gates stop immediately
until another start pulse is given: this closes the automation. A start pulse sent during
closing re-opens the gates.
SUPER AUTOMATIC MODE. When you select this type of operating and a start pulse
is given, the gate opens as far as the limit switch and stays open for the pre-set pause time
and then closes automatically.
A start pulse given during any stage reverses the direction: you can close the gate with
a command.
• A pulse given during the pause triggers pre-fl ashing and subsequent closing of the gate.
DIP-SWITCHES 4 and 5 (GATE CLOSING DELAY) - These SWITCHES are used to
adjust the gate closing delay for motor 1 (delayed closing), compared to the start up of
motor 2 (immediate). It can be set at 0, 3, 9 or 16 seconds.
DIP-SWITCH 6 (PRE-FLASHING) - This SWITCH is used to enable or disable pre-
fl ashing. It is possible for both the opening and closing stages. If the function is enabled,
before the automation opens or closes, there will be a signal for 3 seconds and the
warning light and fl ashing lights will come ON before the gates move.
DIP SWITCH 7 (PAUSE PHOTOCELL) - This SWITCH is used to select the pause
photocell function when the automatic functioning mode is enabled. When the SWITCH
is in the ON position, if the photocell beam is interrupted and cleared with the automation
in pause, the device will command pre-fl ashing for 3 seconds and will then close the
gate, even if the pause time has not been concluded. When the SWITCH is in the OFF
position, the gate will only close when the set pause time expires.
ENGLISH
DIP SWITCH 8 (PEDESTRIAN START OR OPENING SAFETY DEVICE) - This
SWITCH is used to select the type of input for terrminal 6. When the SWITCH is in the
ON position, the input functions as an opening safety device. When the SWITCH is in
the OFF position, the input is enabled for single wing functioning (motor 1).
NOTE - This selection (ON/OFF) is valid for all operating modes, except Dead Man
mode. In this case, the input is always used as the closing input function.
DIP SWITCH 9 - LEAVE IN THE FACTORY-SET POSITION.
DIP SWITCH 10 (ENABLE/DISABLE ANTI-CRUSH CONTROL) - - If the device
controls APRIMATIC electromechanical operator, set the dip-switch to the ON position
(anti-crush card enabled).
If the device controls APRIMATIC hydraulic operators, set the dip-switch to the
OFF position.
4 OPERATING CONTROL
After selecting the operating mode and times, check the external devices connected
to the card and check the state of the LED's.
4.1 CHECK THAT THE EXTERNAL DEVICES ARE OPERATING
CORRECTLY
Start input- N.O. type contact which supplies the start pulse to the automation
Stop input - N.C. safety contact which has priority in all states and functions. If the
stop input is given, the device blocks the gate immediately and it only starts up again
when the start push-button is pressed: this closes the automation. When the stop input
is given, the device ignores all the commands.
Photocell input - N.C. safety contact which is only enabled during closing. If the
photocell is obscured, the automation stops for 1 second and the gates then re-open
until the work time expires. When the gate is open and the photocells are obscured,
the photocells block gate closing.
Pedestrian start - opening/closing safety device input - The function of this input
connected to terminal 6 depends on the setting of SWITCH 8 or on the operating
mode. The following is a list of the possible functions.
Pedestrian start input - When SWITCH 8 is in the OFF position: N.O. contact.
Press the push-button connected to this input to command only one wing (pedestrian
opening). The single wing will follow the set operating mode and, when a start pulse is
given, the automation opens both wings, since the start function has priority over the
pedestrian start input. This pedestrian start input is ignored if the automation has been
commanded with a start pulse and if it is already moving.