Distortion factor
(K < 0.5%)
± 0.2%
Additional errors
Temperature influence
(– 25...+ 55 °C)
± 0.5% / 10 K
Frequency influence
45 – 200 Hz
± 0.5%
Stray field influence
0.5 mT
± 0.2%
Distortion factor
influence (K < 10%)
± 0.4 · K (%)
Influence of range
exceeding at
1.2 x I
resp. U
± 0.25%
N
N
Influence of common-
mode voltage 220 V,
50 Hz or 10 V, 1 MHz
± 0.2%
HF surge voltage influence
acc. to IEC 255-4 Class III,
2.5 kV, 1 kV, 200 Ω
1 MHz, 400 Hz
± 2.0%
acc. to ANSI/IEEE
C 37.90 - 1978
2.5 kV, 150 Ω
1 MHz, 50 Hz
± 1%
Installation data
Mechanical design:
Plug-in module in Euro for-
mat, 100 x 160 mm (see Section
«8. Dimensional drawing»)
Space needed:
Front plate width 7 TE (35.2 mm)
Front plate colour:
Grey RAL 7032
Designation:
EURAX UI 505
Mounting position:
Any
5. Electromagnetic compatibility
The basic standards EN 50 081-2 and EN 50 082-2 were taken in account
Conducted interference from the instrument
HF radiation from complete instrument
Electrostatic discharge
HF field influence on instrument
Transient (burst) via connections
HF interference via connections
The device fulfils the protection requirements of the EMC guidelines (89/336/EWG). The device bears the CE symbol for
EMC.
Electrical
connections:
Coding:
Weight:
Regulations
Impulse withstand
voltage acc. to
IEC 255-4, Cl. III:
Electrical standards:
Housing protection:
Test voltage:
Environmental conditions
Climatic rating:
Operating
temperature:
Storage temperature:
Relative humidity of
annual mean:
Altitude:
Indoor use statement!
EN 55 011
Group 1, Class A
EN 55 011
Group 1, Class A
Direct: ± 8 kV air
IEC 1000-4-2
Indirect: ± 4 kV contact
80 MHz ... 1000 MHz: 10 V/m, 80% AM 1 kHz
IEC 1000-4-3
(ITU-frequencies, 3 V/m)
± 2 kV, 5/50 ns, 5 kHz, > 2 min.
IEC 1000-4-4
capacitively coupled
0.15 to 80 MHz: 10 V, 80% AM 1 kHz
IEC 1000-4-6
(ITU-frequencies, 3 V)
32-pole plug to DIN 41 612, pattern
F and 6-pole plug (contact fitting
see Section «7. Electrical connec-
tions»)
By coding pins, removed/not re-
moved, see Section «7. Electrical
connections»
Approx. 0.6 to 0.75 kg, acc. to
type
5 kV, 1.2/50 µs, 0.5 Ws
Common-mode and differential-
mode between any terminals
Acc. to DIN 57 410
IP 00 acc. to EN 60 529
4 kV, 50 Hz, 1 min.
Climate class 3Z acc. to
VDI/VDE 3540
– 25 to + 55 °C
– 40 to + 70 °C
≤ 75%
2000 max.
17