Servicing and maintenance
Servicing may only be provided by trained persons.
Long operating life and failure-free operation of this high-quality product will be provided by following the servicing instructions
specified in this manual. Disconnect the appliance from the compressed air source for servicing and maintenance purposes. To
ensure permanent failure-free operation of the appliance, everyday cleaning and regular lubrication need necessarily be provided.
For that, special pneumatic oil must be used only. Our special pneumatic oil for oil-fog lubricators #40060 is recommended.
The following options are available for lubrication purposes:
a)
using an oil-fog lubricator
The full maintenance unit includes an oil-fog lubricator (e.g. Güde ¼" SB #41080 lubricator) and is placed on the compressor.
b)
using a pipeline grease box
A grease box (e.g. Güde #41086) sufficiently supplying the appliance with oil is installed on the pipeline in the immediate vi-
cinity of the appliance (distance of app. 50 cm).
c)
manually
If no maintenance unit or pipeline grease box is available for your appliance, 3 - 5 oil drops must be added to the compressed
air connection every time you are going to put the pneumatic appliance into operation. If the pneumatic appliance has been
out of operation for a couple of days, 5 – 10 oil drops must be added to the compressed air connection before starting the ap-
pliance. Keep the pneumatic tools and appliance in dry spaces.
Caution:
Replace the spring (pos. 1) from time to time
Failure – cause - removal
Failure
Cutter not working properly
Service
Any technical questions? Complaint? Do you need spare parts or operation manual?
Go to our website www.guede.com and the section Service will help you quickly and without bureaucracy. Please, help us to
help you. In order to identify your device in case of complaint, please indicate serial number, order number and year of manufac-
ture. All information is available on the product label. To have all information always at hand, put them down.
Serial number:
Order number:
Year of manufacture:
Phone:
+49 (0) 79 04 / 700-360
Fax:
+49 (0) 79 04 / 700-51999
E-Mail:
support@ts.guede.com
Cause
Air control is set to a too low value.
Knife is worn out.
Operating (hydraulic) pressure is too
low.
Too low output of the compressor.
Too small diameter of the hose.
Bypass valve is worn out.
9
Removal
Set the air control to a higher value.
Replace the knife.
Increase the operating (hydraulic) pres-
sure while respecting the maximum op-
erating pressure value.
Use a compressor of different output.
Use a hose of appropriate diameter.
Contact the manufacturer or an author-