2.3.2 Mounting with back cover
According to the model of the clock make the cut-out following le dimensions listed in table below
Style 5
Style 5S
Style 7
Style 7S
Style 7 Date
Style 10
Dimensions in mm
a) Insert the back cover in the cut-out tn order to mark the position of the mountig screws.
b) Remove the back cover and drill 2 holes Ø 6 mm (
cover mounting
c) Drill 4 holes Ø 10mm (
d) Feed the power cable, the synchronisation cable and the keypad cable throught the cut-out and
cable glands of the back cover.
e) Fix the back cover to the wall with the 2 screws Ø 4mm
f) Connect the clock, adjust the brightness (page 7) and set the time (refer to page 10)
g) Fix the clock to the back cover with the 4 screws Ø 4mm
CAUTION: do not fit a DHF clock in a metal partition or equivalent.
A
B
275
400
325
46
440
365
424
Y
X
Y
Y
) to make room for the back cover clock mounting rivets.
Installation with back cover
C
D
241
68
365
68
291
85
404
85
331
200
406
100
X
) to insert the wall plugs.for the back
Back cover mounting screws
EN
E
107
107
117
123
308
165
9