13 - ONBOARD RADIO RECEIVER CONTROL
Storing a new transmitter in memory:
1 - Press and release Learn button.
2 - Led L6 will come on.
3 - Press button 1 of the transmitter to be stored for 2 seconds.
4 - The new transmitter is stored.
5 - Led L6 will stay on for another 5 seconds; during this period, you can store other transmitters, restarting from
step 3.
It ispossible to store up to 200 transmitters.
Clearing the memory:
1 - Press and hold down Learn button for 12 seconds.
2 - Led L6 will initially come on and then go off after 12 seconds.
3 - All the transmitters have now been deleted.
Assigning START and PED commands to the transmitter buttons:
Refer to Figure 17-18 and DIP3 configuration.
14 - GATE TRAVEL LEARNING
The procedure has two phases, completely automatic: the first one of OPENING and CLOSING SPACES
learning and the second one of motors' amperometric values learning.
If using only one motor, it must be connected to the terminals M1.
Intervention of START, PED, PHOTO1, PHOTO2, SAFETY inputs during learning procedure will abort the
procedure and it will be necessary to repeat it from the beginning.
During learning procedure FLASHING LIGHT / WARNING LIGHT will be on.
Travel learning movement is slowed down (50%).
Learning procedure cannot be executed while running on battery.
Learning procedure:
Release the operators and move the gates to halfway their travel.
Ÿ
Lock the operators.
Ÿ
Check that the mechanical opening and closing stops are present on the ground or on the operator .
Ÿ
Remove any obstacles in the range of action of the automated device.
Ÿ
Check that leds L3, L4, L5 and L8 are on.
Ÿ
Press and release MEMO button.
Ÿ
Led L7 will come on, after 30 seconds of no user interaction the control board will quit learning procedure.
Ÿ
Within 30 seconds press again MEMO button in order to choose operator type. At the first stroke L7 will blink
Ÿ
once every 4 seconds and that means MODO12-MEKA BL12-ART3012 is the installed operator; at the second
stroke L7 will blink twice every 4 seconds and that means FLOOR812 is the installed operator.
The operator selection sequence is cyclic.
Press button 1 of the radio control or give a START pulse from the terminal board.
Ÿ
Check that motors' movement is in the correct direction (at the beginning in opening). On the contrary, block
Ÿ
the learning cycle with any safety device, invert the motor cables and repeat the procedure.
BE12