14
UK
1 - TECHNICAL SPECIFICATIONS
Control unit
Type
Power supply
No. of motors
Motor power supply
Flashlight
Accessory power supply
Radio receiver
Operating temperature
Run time
2 - TECHNICAL SPECIFICATIONS/FUNCTIONS
• Red warning LEDs for N.C. contacts and for programming.
• Blue LED for times programming.
• Buttons on the circuit board for programming and learning the radio controls.
• Automatic run time learning with simplified procedure.
• Onboard radio receiver that can store up to 200 radio controls.
• Control of the radio transmitter channels via dip switches.
• Deceleration during opening and closing.
• Deceleration speed adjustable via DIP switch.
• Stop and motion inversion after intervention of the safety devices.
• Amperometric reading of motor absorption, adjustable via DIP switch.
• Pedestrian operation with motor 1 opening.
• Two N.C. inputs, photocell 1, photocell 2.
• One input (SAFETY) programmable as STOP or EDGE.
• Two possible operating logics: step-by-step with stop or condominium selectable via DIP switch.
• Gate phase shift time adjustable via DIP switch.
• Programming of automatic closing and pause time via DIP switch.
• Provision for use with buffer batteries.
• Soft-Start and Soft-Stop to limit mechanical shock.
Thank you for choosing GIBIDI.
READ CAREFULLY THESE INSTRUCTIONS BEFORE PROCEEDING WITH INSTALLATION.
WARNINGS:
This product has been tested by GI.BI.DI. for full compliance with the requirements of the directives in force. GI.BI.DI. S.r.l. reserves
the right to change the technical data without prior notice in relation to product development.
DISPOSAL: GI.BI.DI. advises recycling the plastic components and to dispose of them at special authorised
centres for electronic components thus protecting the environment from polluting substances.
BE12 / AS06260
Electronic control unit for automation
of a double swing gate with 12VDC motors
230 VAC single-phase 50/60 Hz
1-2
12 Vdc
12 Vdc 10W max
12 Vdc 10W max
Integrated, 200 trasmitters maximum
-20°C +60°C