Movements during learning with 2 motors:
• Motor 1 opens until meeting the mechanical end-stops.
• Motor 2 opens until meeting the mechanical end-stops .
• 5 seconds pause.
• Motor 2 closes until meeting the mechanical end-stops.
• Motor 1 closes until meeting the mechanical end-stops.
• Full open-close cycle.
• End of learning; L7 will goes off.
Movements during learning with 1 motor:
• Motor 1 opens until meeting the mechanical end-stops.
• 5 seconds pause .
• Motor 1 closes until meeting the mechanical end-stops.
• It makes a complete manoeuvre, opening, 5 sec. pause and closing.
• End of learning; L7 goes off.
In case the learning procedure cannot be completed, please check LED L7 status (chapter 8).
15 - BATTERY OPERATION
If the backup battery is installed, it is necessary to connect the +12Vdc of all the accessories to the terminal
28 (+BAT).
16 - FLASHING LIGHT SIGNALS SUMMARY
Meaning
Opening
Closing
Photo 2 intercepted in stand-by
in presence of START command
Edge intercepted in stand-by
in presence of START command
Edge intercepted in pause in presence of
START command or at the closing beginning
Low Battery before closing (10V).
Low Battery before opening or closing(9V).
Signal
0,8s ON, 0,8s OFF continuous
0,4s ON, 0,4s OFF continuous
5 fast flashings
3 slow flashings
3 slow flashings
4 slow flashing
4 slow flashing
UK
Effect
The gate is opening
The gate is closing
When released it opens
Blocked closed door
Blocked open door
Blocked door
Blocked open door