16
UK
5 - ELECTRICAL CONNECTIONS: CONNECTORS
FASTON
CF1
CF2
6 - ELECTRICAL CONNECTIONS: TERMINAL BOARDS
Terminal
Position
1
2
M1
3
4
5
6
7
8
M2
9
10
11
12
13
M3
14
15
16
17
18
19
20
M4
21
22
23
24
25
26
M5
27
28
M6
29
0 VAC from transformer
12 VAC from transformer
Signal
Description
M1+
Motor 1+
M1-
Motor 1-
M2+
Motor 2+
Motor 2-
M2-
+
Electric lock power supply
EL+
- Electric lock power supply 12V
EL-
+ FLASHLIGHT power supply 12 VDC MAX 10W.
LAMP/SPIA
- FLASHLIGHT power supply 12 VDC MAX 10W.
LAMP/SPIA
+12Vdc
External accessory power supply
+ACC
External accessory power supply common
-ACC
5V
UNUSED
S1
UNUSED
COM
UNUSED
5V
UNUSED
S2
UNUSED
COM
UNUSED
START input (N.O.).
START
PEDESTRIAN input (N.O.) (DIP 2_7)
PED
PHOTOCELL 1 input (N.C.). Input active only during closing. It stops and inverts the
motion, opening the gate completely. If the gate is closed, it does not affect its
PHOTO 1
functioning. If intercepted during pause, it reloads the pause time.
PHOTOCELL 2 input (N.C.). Input active during both opening and closing.
If intercepted, it immediately stops the motion and holds it stopped until the photocell
PHOTO 2
is freed. Upon release, motion always restarts in opening. If intercepted during pause, it
reloads the pause time.
STOP
Programmable INPUT (STOP – EDGE).
SAFETY
COM
Accessory common.
Accessory common.
COM
IN1
Unused imput.
IN2
Unused imput.
Antenna braid input.
COM
Antenna signal input.
ANT
+BAT
+Battery 12V MAX 3Ah.
-BAT
-Battery 12V MAX 3Ah.