TECHNICAL DATA

GB
Power controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RWF40.000A97
Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110...240 V
Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48...63 Hz
Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 VA
Contact capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AC 24...240 V, 2A at p.f. (cos
Electromagnetic compatibility. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . To NAMUR recommendation NE 21, EN 50 081 part 1, EN 50 082
Protection rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Front: IP 65
Ambient temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 20...+ 50°
Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 40...+ 70°
Max. relative humidity (annual average) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 % (avoid condensation)
Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . At the back, via pug-in screw terminal strips, angled at 45°
Case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mounting depth 130 mm
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . approx. 0,43 kg
The RWF40 power controller conforms to EN 60730 standards.
It is available in 4 models:
Model
D1903
D1901
D1902
It is a universal, configurable device and can be connected to the following probes:
Parameter to be controlled
Temperature
Pressure
PROBE (on request)
Parameter to be controlled
Temperature
Pressure
3010212
3010210
3010220
3010211
Adjustment range
-99,9... +500 °C
0... 2,5 bar
0... 16 bar
AC
+ / - 10 %
part 2
Case: IP 20
Application
RS ... /M burners - modulating version
RL ... /M burners - modulating version
FG ... M burners - modulating version
FL ... M burners - modulating version
GAS 3-4-5-6-7 P/M
GAS 3-4-5-6-7 P/M (USA)
GAS 8-9-10 P/M
P 140-200-300-450 P/G
P 140-200-300-450 P/N
G/M 1400-2000-3000-4500
N/M 1400-2000-3000-4500
Probe
Thermal resistance
Pt100, Pt1000
Ni100, Ni1000 DIN 43760
Ni1000 Landis & Staefa
Thermocouple
Probe with output signal
Probe with output signal
Type of probe
PT 100
Probe with 4...20 mA output
Probe with 4...20 mA output
6
ϕ)
>0,6
-200...
850 °C
-60...
250 °C
-50...
160 °C
J
-200... 1000 °C
K
-200... 1372 °C
N -100... 1300 °C
T
-200...
400 °C
0...
1 V
0...
10 V
0...
20 mA
4...
20 mA
0...
1 V
0...
10 V
0...
20 mA
4...
20 mA
Code
3010110
3010213
3010214