Replacing The Filters; Replacing The Solenoid Valve Cartridge - Franke AQCT0071 Notice De Montage Et De Mise En Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

24. Replacing the filters

Water volume regulator filters
24.1 Remove the shower panel (see
24.2 Unscrew the locking screws (a) on the water volume regulators.
24.3 Replace the filters (b).
Important!
Note the installation position of the filters.
24.4 Reassemble in reverse order.
Solenoid valve cartridge filter
24.5 Remove the solenoid valve cartridge (see
24.6 Use flat-nosed pliers to remove the filter (c).
24.7 Replace the filter.
Important!
Note the installation position. The crosspiece of the filter may not be on top of the
flow hole.
24.8 Reassemble in reverse order.

25. Replacing the solenoid valve cartridge

25.1 Remove the shower panel (see
25.2 Loosen the cable connection between the solenoid valve cartridge and the
electronics module.
25.3 Loosen the screws (a).
25.4 Remove and replace the solenoid valve cartridge (b).
25.5 Reassemble in reverse order.
Chapter
21.).
Chapter
Chapter
21.).
- 15 -
25.).

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aqct007476129822191157612982219085

Table des Matières