18.2 Release the screw (c) and the disk.
18.3 Remove the temperature selector (b).
18.4 Remove the rosette (a).
18.5 Undo the grub screw (f) with an Allen key.
18.6 Remove the headpiece (g) from the wall bracket.
18.7 Remove the rosette (e).
18.8 Remove the safety screws (k) and their locknuts (h) from the cover plate.
18.9 Loosen the cable connection between the optical sensor and the electronics module.
18.10 Remove the cover plate (i).
18.11 Close the water volume regulators (see
18.12 Trigger the fitting.
19. Replacing the filters
Water volume regulator filters
19.1 Remove the cover plate (see
19.2 Unscrew the locking screws (a) on the water volume regulators.
19.3 Replace the filters (b).
☞
Important!
Note the installation position of the filters.
19.4 Reassemble in reverse order.
20. Replacing the solenoid valve cartridge
20.1 Remove the cover plate (see
20.2 Loosen the cable connection between the solenoid valve cartridge and the
electronics module.
20.3 Loosen the screws (a).
20.4 Remove and replace the solenoid valve cartridge (b).
20.5 Reassemble in reverse order.
Work step
Chapter
18.).
Chapter
18.).
10.18).