13. Adjusting the Flow Duration
13.1 Use a screwdriver to carefully prise up the plug.
13.2 Remove the plug.
13.3 Loosen the grub screw using a hollow hexagon wrench.
13.4 Remove the push-cap handle.
13.5 Set the flow duration with a screwdriver.
a: Blade width 3 mm
+ longer flow duration (max. 50 s)
– shorter flow duration (min. 1 s)
13.6 Trigger the valve to measure the flow duration.
☞
Important!
When replacing the handle pressure cap, ensure that the driver bar latches into the
corresponding slot.
13.7 After setting the required flow time, replace the push-cap handle.
13.8 Reassemble in the reverse order.
14. Setting the Temperature Limiter
Warning!
If the hot-water supply temperature is more than 45 °C, set the temperature limiter.
Failure to observe can cause bodily harm due to scalding.
14.1 Remove the push-cap handle (see
14.2 Use a screwdriver to carefully prise off the stop ring and then use your hand to pull it
off from the teeth.
14.3 Mount the push-cap handle and trigger the fitting.
14.4 Turn the push-cap handle until the desired maximum hot-water temperature is
reached.
14.5 Push the stop ring back on the teeth so that the nose of the stop ring is positioned up
against the right-hand stop of the housing.
☞
Important!
While fitting the push-cap handle, make sure that the driving lug locks properly into
the corresponding groove (see
14.6 Reassemble in the reverse order.
15. Maintenance and Servicing
Depending on the quality of the water, the local conditions and the rules and regula-
tions applicable on site, the fitting must be maintained and serviced at regular
intervals.
Chapter
13.).
Chapter
13.).
- 7 -