Hülsta TAMETA III Notice De Montage page 20

Table des Matières

Publicité

Attention! The nature of the wall must be checked carefully by qualified personnel before assembly. Assembly may then only be carried out by qualified persons
carefully observe these assembly instructions. The wall plugs Fischer SX 8x65 in standard set mat. no. 1535746 are only suitable if the characteristics of the wall and the
pressure resistance levels are as stated in the table below. The unit must not be assembled on light walls or masonry. In all other cases it is essential that a different and
appropriate type of mounting is chosen by a qualified person. hülsta cannot be held responsible for the correct choice of a different method of mounting. Please note
that if the units are not mounted properly on the wall, there is a risk of the units falling down or tipping over – especially when alternative mounting materials acquired on site
have been used. Generally speaking, you as a dealer/qualified fitter are responsible for the correct wall mounting of the units.
During assembly please also make sure that there are no electrical installations or other utility lines near the mounting area. This must be checked using an appropriate
search device. Please note that plastic pipes will not be detected.
The standard set mat. no. 1535746 is only suitable for use in connection with the types of walls stated below.
Please note that the pressure resistance levels must under no circumstances fall below those stated.
Concrete
Concrete
SEITE 20
Standard set mat. no. 1535746
4x
SX 8x65
C12/15
Pressure resistance
>/= 15 N/mm²
4x
6x80
Recommended kind of drilling:
Hammer (impact) drilling: Drilling with a hammer drill (high setting,
better drilling progress) for holes which need to be of a high quality.
Suitable for solid walls with a dense structure (concrete, etc). Drilled
holes should be thoroughly cleaned after drilling by blowing or sucking
out any remains.
Percussion drilling: Drilling with a percussion drill (low setting)
for brickwork of a dense structure (solid bricks, solid sand-lime bricks).
Drilled holes should be thoroughly cleaned after drilling by blowing or
sucking out any remains.
Note:
When drilling holes be sure to use sharp drill bits because otherwise the
insertion torque for the screw will be too high and it will therefore be
difficult to insert and tighten it.
The set can be used on walls up to a max. 15 mm of plastering or on any
other non-load bearing surfaces. If this limit is exceeded it may
be necessary to use different mounting methods.