VH / VK
2.2 Insertion installation
The paddle must not hit the pipe wall
must be able to move freely
The paddle must not touch the inside of the
dome
.
Observe the installation height dimensions.
Shortening of paddle (only VHS06, VHS09, VK306,
VK309)
Hold the paddle tight above the cut surface.
Shorten the paddle with a suitable tool to the required
length.
Pipe tee according to EN 10242
Seal the thread of the threaded adapter (G½) with a suitable sealing material (e. g. hemp
or Teflon tape) or sealing rings.
Screw the threaded adapter into the pipe tee.
Welding socket according to EN 10241
(G½ female, length 15 mm)
Weld the welding socket into the prepared pipe.
Seal the thread of the threaded adapter (G½) with a suitable sealing material (e. g. hemp
or Teflon tape) or sealing rings.
Screw the threaded adapter into the welding socket.
Soldering / welding adapter
Remove the flow switch and the O-ring from the soldering / welding adapter
Solder the soldering adapter into the prepared pipe
or
Weld the welding adapter into the prepared pipe.
Install flow switch
Insert the O-ring into the groove.
Insert the flow switch into the adapter and turn the union nut onto the thread (do not
tighten yet).
Align the flow switch in the flow direction.
Tighten the plastic union nut with 7...8 Nm or the metal union nut with 25...30 Nm.
Technical changes reserved