Adjusting the switching unit (optional)
Loosening the locking screw
Loosen the locking screw
sions and cross recess with plastic versions).
Setting the normally open contact
Move the switch unit until the red arrow
guide.
1
Types VHS, VKS and VK3
Setting the normally closed contact
Move the switch unit until the white/blue arrow
unit's guide.
1
Types VHS, VKS and VK3
Setting the setpoint for lower flow
Move the switch unit into the direction of the arrow
tip
.
Setting the setpoint for higher flow
Move the switch unit into the direction of the arrow
end
.
Tightening the locking screw
Carefully tighten the locking screw
2 Nm.
If applicable, secure the locking screw of the switching
unit using varnish / thread-locking fluid after individually
setting the setpoint.
Closing the switch head (only VHS, VKS)
Close the lid until it clicks into place.