INSTALLATION
17.6 Data tables
Item no.
Electrical data
Phase (50/60
)
Hz
Rated voltage
1
Rated output
, jumper position 1 [low] / 2 [high]
Amperage draw, jumper position 1 [low] / 2 [high]
Min. recommended circuit breaker size
3
Min recommended wire size
(copper), jumper position 1 [low] / 2 [high]
Min. resistivity ρ15 ≥
Max. conductivity 15 ≤
Connections
Water connections
Application limits
Maximum permissible pressure
Maximum inlet temperature for reheating
Maximum inlet temperature
User selectable temperature range
Internal anti-scalding protection temperature limiter values
Hydraulic data
Minimum water flow to activate unit
Nominal water volume
Other
Type of installation
Protection class
Insulating block
Heating system
Cover and back panel
Color
Dimensions
Height
Width
Depth
Weights
Weight
DHC-E 3/3.5-1 Trend ships with a 0.5 gpm (1.9 l/min) pressure compensating flow-reducer/aerator that must be installed.
DHC-E 4/6-2 Trend ships with 2 x 0.5 gpm (1.9 l/min) and a 1.0 gpm (3.8 l/min) pressure compensating flow-reducer/aerator that must be installed. See section 11.3, "Aerator
installation at connected faucet," pg. 17 for more information.
1
Factory default setting is jumper position 2 [high]
2
Overcurrent protection sized at 100% of load. Tankless water heaters are considered a non-continuous load. Use only GFCI Class A circuit breakers.
3
Copper conductors with a temperature rating of 75 °C or greater must be used.
These are our recommendations. Check local codes for compliance if necessary.
www.stiebel-eltron-usa.com
2
, jumper position 1 [low] / 2 [high]
DHC-E 3/3.5-1 Trend
DHC-E 4/6-2 Trend
200057
200061
1/N/GND
1/N/GND | 2/GND
120
240
V
3.0
/ 3.5
3.8
kW
kW
25
/ 29.2
15.8
A
A
25
/ 30
20
A
A
10/2
/ 10/2
12/2
AWG
AWG
1100 Ω cm
910 μS/cm
½˝
NPT
145
(1
)
psi
MPa
131
(55
)
°F
°C
149
(65
)
°F
°C
68–140
(20–60
)
°F
°C
100/109/122/140
(38/43/50/60
)
°F
°C
0.264
(1.0
)
gal
l/min
0.07
(0.277
)
gal
l
Over-sink/under-sink
1
Glass-reinforced polyamide
Direct Coil
Plastic
White
14
1
/
˝ (360
)
mm
8
8˝ (202
)
mm
4
5
/
˝ (109
)
mm
16
5.5
(2.5
)
lbs
kg
Conductors should be sized to maintain a voltage drop of less than 3% under load.
208
V
V
/ 6.0
2.9
/ 4.5
kW
kW
kW
kW
/ 25
13.9
/ 21.7
A
A
A
A
/ 25
15
/ 25
A
A
A
A
/ 10/2
14/2
/ 10/2
AWG
AWG
AWG
DHC-E Trend & DHC-E Plus |
AWG
25