14.2 Fault conditions
In the event of a fault, temperatures of up to 95 °C at 1.0 MPa can
occur depending on the type of heat sources used.
14.3 Data table
Hydraulic data
Nominal capacity
Capacity, upper indirect coil
Capacity, lower indirect coil
Surface area, upper indirect coil
Surface area, lower indirect coil
Pressure drop at 1.0 m³/h, upper indirect coil
Pressure drop at 1.0 m³/h, lower indirect coil
Application limits
Max. permissible pressure
Test pressure
Max. permissible temperature
Max. flow rate
Max. recommended collector aperture area
Dimensions
Height
Height incl. thermal insulation
Diameter
Diameter incl. thermal insulation
Height when tilted
Weights
Weight, empty
Weight, full
WWW.STIEBEL-ELTRON.COM
Guarantee
The guarantee conditions of our German companies do not
i18
apply to appliances acquired outside of Germany. In countries
where our subsidiaries sell our products a guarantee can only
h05
be issued by those subsidiaries. Such guarantee is only grant-
ed if the subsidiary has issued its own terms of guarantee. No
i03
other guarantee will be granted.
d01
We shall not provide any guarantee for appliances acquired in
h06
h43
countries where we have no subsidiary to sell our products.
This will not affect warranties issued by any importers.
Environment and recycling
h06
We would ask you to help protect the environment. After use,
d02
dispose of the various materials in accordance with national
i02
regulations.
d25
h28
d26
SBB 600 WP SOL
l
l
l
m²
m²
hPa
hPa
MPa
MPa
°C
l/min
m²
mm
mm
mm
mm
mm
kg
kg
SBB 800 WP SOL
235906
235907
575
770
48
52
16
21
5.7
6.2
2.0
2.6
3.6
3.9
2.4
3.2
1
1
1.5
1.5
95
95
70
90
12
14
1775
1943
1775
2065
750
790
970
1010
1813
1990
244
296
883
1139
SBB 600-1000 WP SOL |
SBB 1000 WP SOL
235908
835
52
30
6.2
3.6
3.9
3.4
1
1.5
95
90
17
2153
2275
790
1010
2185
321
1238
23