Pour the fuel in the filler hole carefully
Never fill the tank above the fuel filter upper edge.
Place the cover back on the filler hole
Initial Operation safety Instructions
No sensitive electronic instruments and HI-FI, television sets, com puters should be connected because of voltage
spikes!
Put the unit on a flat base. Do not put it on a metal base.
Do not expose the unit to strong sunshine and temperatures above 40°C. Do not store it in moist ambient conditions.
Before using it, make sure that the input of the appliance to be connected to the unit is low er than the output of the
generator.
Do not connect the appliance to the generator before the later is running at full. Disconnect the appliance before
sw itching the generator off.
Do not connect other sources to the unit. Do not connect it to the mains .
Immediately sw itch the generator off under conditions as follow s:
- unsteady or uneven engine run
- electrical output decline
- connected appliance overheating
- excessive generator vibrations
- sparkling
- smoke or fire
Make sure that there is enough fuel before connecting the generator to the appliance
Never refuel w hile the unit is running. Before refuelling, let the unit cool dow n for 54 minutes as a minimum after any
use.
Never touch the unit hot parts.
Do not store fuel near the unit.
The silencer and the air filter w ork as flame trap. Make sure that the parts are installed correctly and in perfect
condition.
Operation
Use of Generator „Turning On"
Fig. 6
Open the petrol cock by turning (ON).
Put the choke in the starting position (see sign on the
air filter).
Pull the starting cable slow ly until resistance is felt,
then make a strong pull to start the engine.
When the engine gets heated up, push the choke in
the initial position and w ait for the indicator to light up.
Connect the appliance cable
If the output is overloaded, the overloading fuse w ill trip. The
indicator lights on.
The generator w ill sw itch off automatically at short circuit.