1. Lift the exhaust defl ector (Fig. 16-1) up carefully.
2. Remove the pins (Fig. 16-2).
3. Ease the exhaust defl ector out.
6.2 Replacing the burn plates/inner
bottom
Fig. 17
1
1. Take out the baffl e/exhaust defl ector (see «6.1 - Replacing
the baffl e/exhaust defl ectors»)
2. Take out the side burn plates (Fig. 17 - 1).
3. Take out the rear burn plates (Fig. 17 - 2).
Fig. 18
2
1. Lift out the ash grate (Fig. 18 - 1) and inner bottom plate
(Fig. 18 - 2).
2. When refi tting, follow the same procedure in reverse order.
2
1

7.0 Maintenance

7.1 Cleaning and soot removal
Soot deposits may build up on the internal surfaces of the
fi replace during use. Soot is a good insulator and will therefore
reduce the fi replace's heat output. If soot deposits accumulate
when using the product, they can easily be removed by using
a soot remover.
In order to prevent a layer of water and tar from forming in the
fi replace, you should regularly allow the fi re to burn hot in order
to remove the layer. Your product should be cleaned internally
once a year to ensure the best heating eff ect. It is a good idea
to do this when cleaning the chimney and fl ue pipes.
7.2 Sweeping the fl ue pipe to the chimney
Flue pipes must be swept through the fl ue pipe sweeping hatch
or through the door opening. The baffl e and exhaust defl ectors
must be removed fi rst.
7.3 Inspection of the fi replace
The manufacturer recommends that you carefully inspect your
fi replace yourself after it has been swept/cleaned. Check all
visible surfaces for cracks. Also check that all joints are sealed
and that the gaskets are in the correct position. Any gaskets
showing signs of wear or deformation must be replaced.
Thoroughly clean the gasket grooves, apply ceramic glue
(available from your local dealer) and press the gasket well into
place. The joint will dry quickly.
7.4 Exterior maintenance
Painted products may change colour after they have been used
for several years. The surface should be cleaned and brushed free
of any loose particles before new paint is applied.
8.0 Operational problems -
troubleshooting
Poor draught
Check that the length of the chimney complies with na-
tional legislation and regulatory requirements. (For further
information, see «2.0 Technical Data» and «4.0 Installation
(Chimney and fl ue pipe»).)
Check that the minimum cross section of the chimney is in
accordance with the specifi cation in «2.0 Technical Data».
Make sure that there is nothing preventing the smoke from
escaping: branches, trees, etc.
Seek professional advice and help if you suspect that the
chimney is not drawing properly (too much/too little
draught).