Using the DC kit
7.5
Connecting the DC kit to the power supply
➤ Check that all the connections have been made in accordance with the
instructions.
➤ Check that the roof air conditioner is closed properly.
➤ Connect the electrical connections of the components ( ECL-76).
➤ Connect the 230 V connection on the roof air conditioner to the socket on the
PP1002 inverter ( PP1002).
➤ Connect the positive battery cables to the batteries.
➤ Check the following are working properly:
– Check the on and off values for the charging voltage regulator
– Check the priority circuit
– Switch on the air conditioning in driving mode ( air conditioning)
– Switch on the air conditioning on mains operation
➤ Adapt the roof air conditioner software to AC/DC operation ( CA1000).
8
Using the DC kit
The DC-Kit1 consists of several components, each with its own installation and
operating manual. Use the installation and operating manuals for the components
and make sure you are familiar with the individual devices.
This chapter contains information on operating the overall system. This operating
manual does not replace any information contained in the installation and operating
instructions for the components.
I
NOTE
The operating noises made by the roof air conditioner are slightly louder
during mobile air conditioning than during stationary air conditioning.
The noises are caused by using the inverter.
12
DC-Kit1
EN