1-528050-0
Connect the colour coated, fourfold air hose on the
back of the machine (Fig. 8.01) and to the double
foot pedal (Fig. 8.02).
Green hose
→ A1 Green
White hose
→ B1 White
Black hose
→ A
Blue hose
→ P
Use the pneumatic Parallel Crimp Machine AT-SC MK II only with conditioned air (lubricated and filtered).
Standard Filter: 30 µm.
Connect AIR MAX. (Fig. 8.01) of the pneumatic Parallel Crimp Machine AT-SC MK II to the main air
supply with the included black air hose Ø 8/6 mm.
Working Air Pressure: 6 bar/87 psi.
CAUTION!
Connect compressed air supply with supplied compressed air tube (length 1m).
The machine can only be depressurized by disconnecting the machine from the
main air supply (Air Max.).
INFORMATION:
Use only lubricated and filtered compressed air.
8.2
Reset of the adjusting mechanism to factory setting
The crimp height of the pneumatic Parallel Crimp Machine AT-SC MK II is already adjusted for the usage
of the different TE-die sets. No changes of the crimp height are necessary.
DANGER!
Due to the risk of hand or finger injury, never try to reach into the machine before
having assured that the machine is disconnected from the air supply.
Black
Blue
Page 48 / 94
412-94233 REV. D1
Air Max.
Fig. 8.01
Fig. 8.02