Technical Data; Release Button; Power Button; Operation Of The Double Foot Pedal - TE Connectivity AT-SC MK II Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1-528050-0
6.2

Technical Data

Dimension:
Length overall:
Width:
Height:
Weight with double foot pedal:
Air pressure:
Air consumption per stroke:
Crimp Force at 6 bar:
Stroke:
Noise level:
6.3

Release Button

In case of a jammed adapter caused by operation
or handling errors or wrongly placed terminals the
jaws can be opened as follows:
-
Press Release Button.
6.4

Power Button

Please push the power button (1) to start the
pneumatic Universal Crimp Machine. In case of a
separation from air, fall of pressure or operation of
the release button the pneumatic Parallel Crimp
Machine
AT-SC MK II will be disconnected.
6.5

Operation of the Double Foot Pedal

The left foot pedal opens and closes the adapter.
The right foot pedal activates the actual crimping
cycle.
390 mm (15'')
175 mm (7'')
440 mm (17'')
approx. 26 kg (57 lbs)
max. 6 bar (87 psi)
2.3 l
max. 35 kN (7868 lbf)
approx. 15 mm (0,6'')
62 dB (A)