Faults
Use only MESTO spare parts and accessories
Fault
No pressure builds up in
the device.
pump.
Piston pressure gauge
does not indicate any
pressure.
Safety valve blows off
too early.
The nozzle does not
spray even though pres-
sure is present.
The shut-off valve does
not close.
Liquid emerges without
the lever being activated.
Contact address for additional information
AUS
USA
Cause
The pump is not screwed on
tightly.
O-ring [14] on the pump is
faulty.
Diaphragm [15] is defective.
Valve disc [17] dirty or defec-
tive.
Piston pressure gauge [8] is
defective.
Nozzle [18]
is clogged.
O-rings [26] of the pressure
bolt [27] not greased / lubri-
cated.
Pressure bolt [27] or
O-rings [26] defective.
18
NZ
Remedy
Screw the pump on tightly.
Replace the O-ring.
Replace the diaphragm.
Clean or replace the valve disc.
Replace the piston pressure
gauge.
or / and
Grease the O-rings [26]
Replace the pressure bolt or
O-rings.