Changing The Lamps; Fault Rectification - Berbel BKH 80 ST Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Maintenance
6.2.2

Changing the lamps

The device is fitted with maintenance-free LED lighting.
In the event of a fault:
☞ Please consult your dealer or customer services.
6.3

Fault rectification

Possible faults are described below:
Description of the fault.
y Possible cause.
☞ Remedy.
Fan and lighting do not work.
y No power supply.
☞ Check that the all-pole mains switch is connected.
☞ Switch the mains switch on.
y The breaker may have been tripped or is defective.
☞ Check to see if the breaker has tripped.
☞ If you use electric circuit breakers, turn the circuit
breaker on again.
☞ For other types of fuse, consult a qualified electrician.
The fan does not work.
y The device is not switched on.
☞ Check all power levels.
D "4.3 Normal operation" (page 104).
y The device is connected to a window contact switch and
the window is closed.
☞ Open the window.
y The device is connected to an under-pressure monitor.
The under-pressure monitor detects a critical under-
pressure.
☞ Open a window.
☞ Wait until the air pressure returns to normal.
The lighting does not work.
y The lamp has blown.
☞ Please consult your dealer or customer services.
Smells occur during operation.
y The filter filling is used up.
☞ Change the filter filling.
D "6.2.1 Replacing filter filling" (page 108).
Poor device performance.
y The recirculated air filter is clogged.
☞ Replace the filter filling of the recirculated air filter.
D "6.2.1 Replacing filter filling" (page 108).
6003417_a – 26.09.2017
Control panel does not react after being touched several times.
y The control panel is soiled.
☞ Clean the control panel.
D "5. Cleaning" (page 106).
y The device software requires a restart.
☞ Briefly disconnect the mains power supply.
Moisture in the device.
y Dripping or splashing water has penetrated the device.
y Liquid (e.g. from vases, bottles on the device) has
penetrated the device.
☞ Immediately shut off the power supply, by removing
the fuse.
☞ Make sure that the power supply cannot be
unintentionally reconnected. For example by tasking
a person with ensuring that the fuse/breaker is not
restored/switched on.
☞ Ensure that no more liquid can penetrate the device.
☞ Allow the device to dry.
☞ Have the device checked and repaired by qualified,
specialist personnel prior to using the device again.
If a fault persists:
☞ Please consult your dealer or customer services.