START UP
Testing the electrical system
•
Switch on the appliance following the instructions for use and cheek the operation of the control devices
and plate heating elements.
•
Test the various operating temperatures.
•
If necessary, consult the Troubleshooting guide to identify the problem.
Testing the rated thermal power
•
Always cheek the thermal power of the appliance after installation and following maintenance work.
•
The rated thermal power is indicated in the "Technical data" table.
INSTRUCTIONS FOR USE AND MAINTENANCE
WARNINGS
•
Beware of the appliance's hot surfaces!
•
This appliance is intended for professional use and must only be used by trained staff. This appliance is
exclusively designed to cook food. Any other use shall be deemed improper.
•
IMPORTANT : Do not operate the heating elements when the tank is empty.
•
In the event of fault, disconnect the electric connection of the appliance.
•
Only contact the technical service centre authorised by the manufacturer and only use original spare
parts.
•
Before using the appliance for the first time, thoroughly clean all the food contact surfaces.
•
For the cleaning, fill the tank up to the upper table with water and detergent. Boil the water for a few
minutes, clean it and in the end rinse with clean water.
•
The thermocouple stops the gas circuit in cases of overheating of the water, so it provides the operation
security.
TROUBLESHOOTING GUIDE
The tank heating elements do not heat up
•
Check the fuses.
•
Main power switch not ON.
•
Low voltage or incorrect electrical connection.
•
Switch faulty.
•
Temperature control thermostat faulty.
•
One or more plate heating elements incorrectly connected or burnt out (replace faulty heating element).
The temperature control is difficult or impossible to regulate
•
Temperature control thermostat faulty.
•
One or more plate heating elements incorrectly connected or burnt out (replace faulty heating element).
REPLACEMENT OF SPARE PARTS
IMPORTANT : Before carrying out maintenance work or repairs, disconnect the appliance from the power supply
at the isolating switch.
Thermostat and switch
•
Remove the upper control panel.
•
Detach the bulb from the thermostat or switch fixed to the heating element by special support brackets.
•
Disconnect the electrical connections.
•
Replace the part.