Energy Savings" Mode; Water Filtering - Jacuzzi delfi pro Manuel D'installation

Masquer les pouces Voir aussi pour delfi pro:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 35
clock
pump 1
pump 2
blower
spotlight
u The pumps and the blower are turned on at preset intervals,
depending on the temperature:
- temperature between 12 and 15 ° C (54 - 59 °F): every hour
- temperature between 9 and 12 ° C (48 - 54 °F): every 30 minutes
- temperature between 6 and 9 ° C (42 - 48 °F): every 15 minutes
- temperatures at or below 6 ° C (42 °F): continuous
NOTES
- If the temperature of the compartment drops rapidly, the frequen-
cy of activation increases.
- If it becomes necessary to turn on the anti-freeze protection du-
ring the filtering or rapid filtering ("Istant Clear") cycles, those cycles
will be suspended and they will resume when the anti-freeze cycle
is complete.
- If this protection is active, the spotlight may still be turned on.

"Energy savings" mode

When this function is set, the electric heater is not turned on until the
water temperature drops at least 10 °C (18 °F) below the set point.
u Press the "Econo"
key. The display shows the message
Edx, where "x" indicates the duration in hours.
u Use the "Up"
and/or "Down"
duration, from a minimum of 0 to a maximum of 24, which means
the function is always on.
u Press the "Econo"
key again to confirm the selected value.
You will then go to the start time (Es).
u First set the hour and confirm with the "Econo" key. Then set
the minutes, and press the "Econo" key again to memorize the
set values and exit programming.
filtering cycle
adjustment
temperature
heating
saving
energy
panel lock
keys to enter the desired
When the function is on, the display will shown the respective
symbol.
u To deactivate the function, set the duration time to 0 (zero).
NOTES
- If a function is turned on (except for the spotlight and/or the time)
when energy savings is present, energy savings is suspended, and
the symbol on the display flashes. It restarts automatically 40 minu-
tes after the function that was started is turned off.
- The minimum temperature that characterizes energy savings
mode may never be less than 15 °C (59 °F) (minimum maintenance
temperature).
- If there is a power outage, the set data are stored in memory. Ho-
wever, when the power comes back on, the function does not resu-
me. Rather, it is turned on at the set start time.
In addition to the parameters "I1x" (temperature unit of mea-
sure) and "I2x" (limitation of electrical energy consumption),
there is also parameter "I3x", the "x" default value of which is
0. Do not change the setting; otherwise, the electric heater
will be turned off.

■ Water filtering

Water filtering is essential to keep the water clean and clear, and
to get rid of suspended particles. This cleaning is provided by the
filtering pump and the cartridge filter(s) located under the skimmer
(see the chapter "Maintenance of the cartridge filter").
The spa is also equipped with a special kind of filtering called "In-
stant Clear". This is instantaneous filtering, which differs from the
normal cycle due to its brief, intense duration.
29
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Delos proSantorini pro

Table des Matières