4:
Combination of time controlled chilling and temperature controlled chilling
with probe.
1. Storage program.
If this program is selected, the cabinet operates as a normal refrigerator/freezer and
is controlled by the set temperature.
2. Time-controlled chilling.
The compressor runs continuously until the set time has elapsed. The control then
changes over to the storage program.
3.Temperature-controlled chilling with probe.
The compressor runs continuously until the set probe temperature is reached. The
control then changes over, to the storage program.
4.Combination of time-controlled chilling and
temperature-controlled chilling with probe.
Combined time and probe temperature control operates as follows:
1.
If the set probe temperature is reached before the set time has elapsed,
this probe temperature is maintained until the time has elapsed. The
control then changes over to the storage program.
2.
If the set probe temperature is not reached before the set time elapses,
chillingcontinues until the set probe temperature is reached. The control
then changes over to the storage program.
Program and
program sequence setting
The program keys
righthand corner.
In
the LED will either flash or light up continuously. (Each time the program key
is pressed the function will change).
1.
Flashing LED indicates that the program has not been started. The
cabinet is ready for programming.
2.
LED continuously on indicates that the program has been started.
76-504-0656
contain a red LED (light emitting diode) in the top
18