In
the LED will either flash, light up continuously or remain out. (Each
time the program key is pressed the function will change).
1.
If the LED is out, the program has not been started.
2.
Flashing LED indicates that the program has not been started, but the
cabinet is ready for programming.
3.
LED continuously on indicates that the program has been started.
Storage program.
Program setting.
Press
and the LED will flash. The actual temperature in the cabinet will be
displayed. The set temperature can be displayed by pressing one of the arrow keys.
(If a change of temperature setting is required, see section "Changing temperature
and time settings").
Program sequence.
The storage program can be started by pressing
continuously.The display shows the cabinet temperature. The set temperature can
be displayed by holding down one of the arrow keys.
(If a change of temperature setting is required, see section "Changing temperature
and time settings").
The storage program can be stopped by pressing
The storage program cannot be stopped when one of the other programs is running.
If one of the other programs is running, the set temperature can be seen on the
display by pressing
Time-controlled chilling.
Program setting.
Press
; the LED will then flash and the set time will be displayed.
(If a change of time setting is required, see section "Changing temperature and time
settings").
Program sequence.
The program is started by pressing
The display alternates each 5th second, between cabinet temperature and remaining
program time. The set time can be displayed by holding down one of the arrow keys.
(If a change of time setting is required, see section "Changing temperature and time
settings").
76-504-0656
. When the LED flashes, press an arrow key.
. The LED will light up continuously.
. The LED will light up
. The LED will flash.
19