The program is stopped and the LED goes out when the program time has elapsed.
(The program can also be stopped by pressing
. The LED will go out.
Subsequently the control switches over to the storage program.)
Temperature-controlled chilling with probe.
The probe is stuck into the product, so that the probe head is placed as close to the
middle of the product as possible.
The compressor runs continuously until the set probe temperature has been
reached. After this the control changes over to the storage program.
Program setting.
Press
; the LED will then flash and the set probe temperature will be displayed.
(If a change of temperature setting is required, see section "Changing temperature
and time settings").
Program sequence.
The program can be started by pressing
. The LED lights up continuously. The
display alternates every 5th second, between cabinet temperature and current probe
temperature.
(If a change of temperature setting is required, see section "Changing temperature
and time settings").
The program is stopped and the LED goes out when the set probe temperature is
reached.
The program can also be stopped by pressing
. The LED will go out and the
control switches over to the storage program.
Combination of time-controlled chilling and
temperature-controlled chilling with probe.
Program setting.
The storage program, time-controlled chilling program and temperature-controlled
chilling with probe program must be set as described under the headings above.
Program sequence.
The program is started by pressing
and
. The LEDs will light up
continuously. The order in which the programs are started is of no importance. The
display alternates every 5th second, between probe temperature and programmed
time.