Temperature setting
Temperature control:
P
Temperature regulation:
Temperature up:
Temperature down:
Error codes on the display
F1
If code F1 is displayed it means that the cabinet temperature sensor is
defective and service assistance should be requested. In the meantime the
cabinet itself will maintain the set temperature by the memory of the
controller.
F2
If the display alternates between temperature and error code F2 there are
problems with the temperature sensor on the evaporator. This has no effect
on the operation of the cabinet, but the sensor should be replaced as soon
as possible. Request service assistance.
F3
If the display alternates between temperature and error code F3 there are
problems with the temperature sensor on the condenser. This has no effect
on the operation of the cabinet, but the sensor should be replaced as soon
as possible. Request service assistance.
NOTE! Applies only to cabinets with built-in compressor.
. . .
If the dots in the display flash, it indicates that the condenser temperature is
too high. Switch off the cabinet at the mains and see whether the condenser
has been covered. If this is not the case, the high temperature might be the
result of dirt on the condenser. The condenser can be cleaned with a brush
or vacuum cleaner. Switch on the cabinet again. After an hour, the cabinet
should run normally. If the dots begins flashing again, request service
assistance.
NOTE! Applies only to cabinets with built-in compressor.
76-504-0930
Press to see the cabinet temperature setting; the display will
show the set temperature.
P
Keep
pressed. At the same time, press
+
Each time
is pressed the temperature will change one
degree. When the display shows the desired temperature let go
of the two keys and the setting has been made.
P
Keep
pressed. At the same time, press
-
Each time
is pressed the temperature will change one
degree. When the display shows the desired temperature let go
of the two keys and the setting has been made.
+
.
-
.
19