Tools Required; The Indoor Lighting Receiver In Detail; Components; Technical Data - SOMFY 2401073 Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Indoor lighting receiver

3.2 Tools required

Appropriate screwdriver for the screws to be used
Insulated fl athead electrician's screwdriver
Drill and drill bit
Pencil

4. THE INDOOR LIGHTING RECEIVER IN DETAIL

4.1 Components

A. PROG button
B. Indicator light
C. Manual On/Off control button
D. Fuse
E. Electrical connection terminal.

4.2 Technical data

Dimensions in mm (H x w x d): 80 x 80 x 45 mm
Operating temperature: + 5°C to + 40°C
Index protection rating: Inside use, in a dry room - IP 30
Frequency: 433.42 MHz
Range: 20 m through two concrete walls; 200 m in open space
Power supply: 230 V; 50 Hz
Fuse: 3.15 A
Power: 500 W max.

5. MOUNTING THE INDOOR LIGHTING RECEIVER

5.1 Before mounting the indoor lighting receiver

5.1.1 Distances
Minimum distance to be kept between an indoor lighting receiver and the ground: (e.g. 150 cm between any RTS control
points and/or between any control point and any motor).
Minimum distance to be kept between an indoor lighting receiver and another RTS component: (e.g. 30 cm between any
RTS control points and/or between any control point and any motor).
Minimum distance to be kept between two indoor lighting receivers: (e.g. 20 cm between any RTS control points and/or
between any control point and any motor).
5.1.2 Conditions
Attention: Do not attach the indoor lighting receiver to a metal surface.
The indoor lighting receiver is only to be installed indoors.
Mount the indoor lighting receiver in a housing for recessed mounting which is 60 mm in diameter (minimum depth: 40
mm) or in a Somfy housing for surface mounting (not supplied).
Always leave the indoor lighting receiver's front panel clearly accessible; never place anything in front.
Check the radio range after the indoor lighting receiver has been mounted. The radio range is limited by the radio
appliance control standards.

5.2 Recessed mounting

Somfy recommends fi tting the indoor lighting receiver in place of the original switch.
[1]. Check that the bulbs work.
[2]. Switch off the power supply (fuse removed or circuit breaker off).
[3]. Remove the original switch to access the housing for recessed mounting.
[4]. Screw the mounting bracket (5) onto the housing using the screws supplied.
Attention: If the screws provided are lost, do not use roundhead screws. Only use fl athead screws with a diameter of 3 mm.
3
A
B
C
E
D
5
Copyright © 2015 Somfy SAS. All rights reserved.