When the set charge start time is reached the station will show the following screen indicating that the
charging process has started correctly.
Ending the charge process
7.
To finish the charge cycle identify the card using the reader. The station interrupts the electric supply and
unblocks the mode 3 and type 2 connector if one of them has been used.
8.
Pull out the connector.
The station will return to the awaiting vehicle status.
Loss of supply (immediate charge and deferred charge)
When faced with a loss of electricity supply the station remains inactive until the supply is restored.
After the supply is restored the station automatically restarts and switches to the status active before the supply
was lost.

9.3. Languages (INGEREV GARAGE One, INGEREV GARAGE Wall)

The information of each user session is displayed in the language configured on each card, regardless of the
default language configured in the station.
In the case of users with no language configured, the station displays the information in the default language set.

9.4. Incidents

The incident can be caused by different reasons. The charging station switches to incident status. On INGEREV
GARAGE Wall and INGEREV GARAGE One charging stations the stop reason is indicated on the display.
Contact the technical service to resolve the incident.
Fault in the installation (error code 0001)
The station protections have tripped.
The station detects that the fault persists in the installation and the protections will not be restored until the fault
disappears.
The electrical installation must be checked by qualified personnel.
Interrupted supply (error code 0002)
Absence of electricity grid. There is no electricity supply. The station restarts when it is restored.
The protections have tripped. The protections have tripped but the fault causing the trip has disappeared.
In the case that unit has resettable protections, the station will reset the protections shortly.
Connector powered (error code 0008)
The connector is powered when it should not be or is not powered when it should be.
Inform the technical service of the incident.
Energy meter communication fault (error code 0016)
The internal communication with the energy meter is not correct, possibly due to a trip of the protections. Proceed
to check the electric installation with a qualified personnel to check if protections have tripped.
36
CHARGING
CHARGING
ABA2021IQM01_A - Installation and Operation Manual