ENGLISH
2) Soak the Scoop in the solution for more than 3
minutes. Rinse thoroughly, and shake to remove
surplus liquid.
Note: Using a cloth to dry may re-contaminate.
[3] Storage Bin Interior Cleaning/Sanitisation
(Weekly)
1) Open the Storage Bin Door, and remove all ice.
2) Remove the Thumbscrews securing the Baffle.
3) Remove the Baffle from the Bin.
4) Wash the Bin liner and Baffle with a neutral non-
abrasive cleaner. Rinse thoroughly.
5) Either mix 5 litres of water with 18 ml of 5.25%
sodium hypochlorite solution in a suitable
container, or the recommended Hoshizaki
sanitiser as directed.
6) Soak a clean sponge or cloth with the solution
and wipe the Bin liner surfaces and Baffle.
7) Refit the Baffle and Thumbscrews. Wipe the
surface of the Bin Door and Thumbscrews with
the solution. Close the Bin Door.
8) The remaining solution can be used to sanitise
utensils.
Note: Do not wipe dry or rinse after sanitising, but
allow to air dry.
[4] Storage Bin Door
Clean the Storage Bin Door at least once a week,
using a neutral non-abrasive cleaner. Rinse
thoroughly after cleaning and sanitise as required.
[5] Air Filter
Plastic mesh Air Filters remove dirt or dust from
the air, and keep the Condenser from getting
clogged. If the Filters get clogged, the icemaker's
performance will be reduced. Remove and clean
the Air Filters at least twice per month:
1) Slide the Air Filter off the Louver.
2) Clean the Air Filter by using a vacuum cleaner.
When severely clogged, use warm water and a
neutral cleaner to wash the Air Filter.
3) Rinse and dry the Air Filter thoroughly, and
place it in position.
Air Filter
Louver
2. SERVICE CALL
WARNING
Do not damage the refrigerant circuit.
[1] Error Code Indication
If the error code "E" is indicated on the display,
before calling for service, check the following.
Code
E0
Possibility of water leaks. Turn OFF Operation Switch,
and turn it ON again. If error code appears again, call
for service.
E1
Low ice production. Turn OFF Operation Switch, and
turn it ON again. If error code appears again, call for
service.
E2
Water supply circuit failure. Turn OFF Operation Switch,
and turn it ON again. If error code appears again, call
for service.
E3
Gear Motor failure. Turn OFF Operation Switch, and
turn it ON again after 10 minutes. If error code appears
again, call for service.
E4
Abnormal high side pressure. Clean Air Filter. Check
that icemaker is properly installed according to
Installation Manual. Turn OFF Operation Switch, and
turn it ON again. If error code appears again, call for
service.
E5
Electric circuit failure. TTurn OFF Operation Switch, and
turn it ON again. If error code appears again, call for
service.
E8
Compressor could be overheated. Check that icemaker
is properly installed according to Installation Manual.
Turn OFF Operation Switch, and turn it ON again after
10 minutes. If error code appears again, call for service.
EA
Electric circuit failure. Turn OFF Operation Switch, and
turn it ON again. If error code appears again, call for
service.
Eb
Electric circuit failure. Turn OFF Operation Switch, and
turn it ON again. If error code appears again, call for
service.
EC
Electric circuit failure. Turn OFF Operation Switch, and
turn it ON again. If error code appears again, call for
service.
EE
Gear Motor failure. Turn OFF Operation Switch, and
turn it ON again. If error code appears again, call for
service.
EF
Supply voltage is too low. Check that voltage is in
required range and icemaker is not sharing a single
receptacle with other appliances. Turn OFF Operation
Switch, and turn it ON again. If error code appears
again, call for service.
4
Fig. 2
Remedy