USING THE FLUSH VALVE
Using the Toilet Flush Valve
Infrared Sensor
The infrared sensor detects
a user of the toilet.
Using the Urinal Flush Valve
Infrared Sensor
The infrared sensor detects
a user standing within
2 ft (600 mm) of the front of
the urinal.
Common
Manual Flushing Button
Use the manual flush button
for maintenance and/or
emergencies.
Flushing
When the user stays in place
longer than 6 seconds then
moves away, the controller
sends a signal to the operating
unit to automatically trip the
Flush Valve after 3
seconds delay.
Flushing
When the user stays in place
longer than 6 seconds then
moves away, the controller
sends a signal to the operating
unit to automatically trip
the flush. (No delay)
11
Flushing Every 24 hours
If toilet is not used for 24 hrs,
the system automatically
flushes as a maintenance
and hygienic precaution.
Flushing Every 12 hours
If urinal is not used for 12 hrs
the system automatically
flushes as a maintenance
and hygienic precaution.