ADJUSTING MAXIMUM OUTLET TEMPERATURE

1. Shut the water off at the stop valves.
2. To decrease temperature:
Remove cap and screw and pull handle slowly to remove.
Turn handle counter-clockwise one notch and reinstall onto cartridge.
To increase temperature:
Remove cap and screw and pull
handle slowly to remove.
Turn handle clockwise one notch
and reinstall onto cartridge.
3. Secure handle with screw and cap.
4. Open shut off valve.
5. Check water temperature.
**Repeat steps 1-5 if necessary
1. To decrease temprature:
Turn handle clockwise.
2. To increase temprature:
Turn handle counter-clockwise.

ACCESSING ANG CLEANING THE VALVE

1. Shut the water off at the stop
valves.
2. Disconnect supply hoses.
3. Pull out the strainer and clean it
with a brush.
4. Reinstall the clean strainer and
connect water supply hoses.
5. Open the stop valves.

ADJUSTING OUTLET TEMPERATRURE