From the CP Display, press the SELECT key: the first SP parameter will appear. Press the SELECT key to change the parameter value and then the UP or DOWN key to change its value.
Confirm by pressing the SELECT key again. Press UP or DOWN to scroll through the menu.
NUMBER
SP
Setpoint
diF
Setpoint temperature differential
When the setpoint temperature has been reached and the compartment temperature remains within diF °C/F above or below the setpoint, there is no demand for
heating or cooling from the unit and it runs in Null mode. Increments of 1º.
SPL
Setpoint temperature minimum value
SPH
Setpoint temperature maximum value
dnS
Compressor delay.
Once the unit is running, the vehicle compressor will start after the delay selected by the dnS value.
In-Cab Control Box
If no key is pressed within 10 seconds, the cab control box will return to the Standard Display.