DISPLAY, LED INDICATORS AND KEYS
1. Display. Remains off when the unit is in standby mode. Normally shows the return air
temperature when activated.
2. ON-OFF Key. The unit is turned on or off by holding the key down for 2 seconds.
3. Select Key. Used to select the setpoint display.
4. Up Key. Used to increase the setpoint.
5. Down Key. Used to decrease the setpoint.
6. STANDBY LED Indicator. When the indicator is lit and the display is off, this
indicates that the unit is in standby mode.
7. SET LED Indicator. Lights up when the unit is in the mode used to adjust the
setpoint.
8. Compressor LED Indicator. Lights up when the compressor is operating, remains
off when the compressor is not operating and flashes when the compressor is about to
begin operating following the normal delay between the unit being turned
on and compressor start-up.
In-Cab Control Box
9. ºC LED Indicator. When lit, indicates that the temperature displayed is in degrees
Celsius (ºC).
10. ºF LED Indicator. When lit, indicates that the temperature displayed is in degrees
Fahrenheit (ºF).
11. Temperature Sensor Alarm LED Indicator. Lights up when the evaporator
return temperature sensor fails.
INSTALLATION MENU
1.
From the Standard Display, press the SELECT key for 5 seconds to access the
Installation Menu. The display for entering the password 'PA1' will appear.
2.
Press the SELECT key, and the number 0 will appear on the display.
3.
Press the UP key until the number 13 appears on the display. Confirm the password
by pressing the SELECT key again. The Compressor Regulator (CP) Menu Display
will appear.
4.
Once at the Compressor Regulator (CP) Menu Display, there are two options:
a.
Press SELECT to go to the Compressor Regulator (CP) Menu, or
b.
Access the diS (Display) Menu by pressing the UP or DOWN key.