• Resolution
• Accuracy
- Range 1: radio
- Range 2: power network
- Range 3: transmitter
Power supply
Operating time
Temperature range in accordance with DIN EN 60068-1
• Operation
• Storage
Weight
Dimensions (W x H x D)
Type of protection in accordance with EN 60529
Dust and water protected
T-3500
The following parameters are specified for the T-3500 transmitter:
Transmitted power
Frequency
Power supply
Operating time
Temperature range in accordance with DIN EN 60068-1
• Operation
• Storage
Weight
Dimensions (W x H x D)
Type of protection in accordance with EN 60529
Dust and water protected

MAINTENANCE

Changing the battery in the R-3500 receiver

The status of the receiver's batteries is checked upon start-up and indicated in the display.
The system regularly checks the battery strength as well. If battery capacity falls below 10 % of the threshold value, an audible
warning signal is given and the current status of the batteries is shown in the upper part of the display.
0.1 m
±20 %
±20 %
±5 % (>5m (6-FT)), ±20 % (<5m (15-FT))
10 x IEC R6 / AA cell / Mignon
40 hours (for intermittent use with alkaline batteries, 20 °C)
-20 °C to +55 °C
-30 °C to +70 °C
2.5 kg, 5.51 lbs.
99 x 660 x 252 mm, .3.90 x 25.98x 9.92 in
IP 67 from the lower edge of the receiver up to the lower edge of the battery
compartment, and IP 56 for all parts above this delineation
0.1 W / 0.5 W (switchable)
32.768 kHz
6 x IEC R20 / D cell / Mono
40 hours (for intermittent use with alkaline batteries, 20 °C)
-20 °C to +55 °C
-30 °C to +70 °C
1.7 kg, 3.75 lbs.
260 x 255 x 140 mm,
IP 56